-40%
Hi-accuracy 0.05% Bench LCR Meter 100KHz 34Points DCR 4.3'' TFT LCD USB RS232C
$ 505.82
- Description
- Size Guide
Description
TH2830Brief Introduction
Adopting the latest technology & high density circuit design and concentrating the essence of LCR test, TH283X series is a new generation compact LCR meter of low cost and high performance. Instead of traditional mechanical power switch, it adopts software control power switch. The basic accuracy of 0.05% and good test stability can compare favourably with those high-end models. Being equipped with 4.3 inch TFT LCD Display and brand new interface system, TH283X series LCR meters possess elegant appearance and easy operation. Also, being provided with various interfaces and good compatibility with SCPI commands, TH283X series LCR meters are convenient for constituting all kinds of test system and satisfy various kinds of demands for inspection, production and scientific research.
Features
■
Low cost, high performance, small size
■
4.3 inch TFT LCD Display
■
Soft power switch
■
Selectable Chinese and English operation menu
■
Max. 200kHz test frequency
■
Max. 6 digit reading resolution
■
10mVrms-2.0Vrms programmable signal level, built-in 0 - ± 5V/50mA bias source
■
DCR, 50mV-2V programmable test level, resolution 10μΩ
■
Ls-Rd / Lp-Rd Function (L, Rd display simultaneously) *
■
Highest test speed 13ms/time
■
Selectable 30Ω/100Ω signal source impedance
■
V/I monitor and auto level adjustment function
■
Built-in comparator, 10 bins sorting and count function
■
File storage and firmware update through U disk
■
RS232, USB, RS485(option), HANDLER, GPIB(option) interface
Specifications
Model
TH2830
TH2831
TH2832
LCRZ
0.05%
0.1%
0.05%
Basic measurement
DCR
0.1%
accuracy (See details in
Warm up time: ≥ 30 minutes ; Environment temperature: 23±5ºC
technical specification)
Calibration condition
Signal level: 1Vrms ; Corretion: after OPEN, SHORT
Testing cable length: 0 m
50Hz-100kHz
,
34points
50Hz-200kHz
, 37 points
20Hz-200kHz
,
50Hz, 60Hz, 75Hz, 100Hz,
50Hz, 60Hz, 75Hz, 100Hz,
15025 points
120Hz,150Hz,200Hz,250Hz,
120Hz,150Hz,200Hz,250Hz,
300Hz,400Hz,500Hz,600Hz,
300Hz,400Hz,500Hz,600Hz,
Test signal frequency
750Hz,1kHz,1.2kHz,1.5kHz,
750Hz,1kHz,1.2kHz,1.5kHz,
2kHz, 2.5kHz, 3kHz, 4kHz,
2kHz, 2.5kHz, 3kHz, 4kHz,
5kHz, 6kHz,7.5kHz,10kHz,
5kHz, 6kHz, 7.5kHz,10kHz,
12kHz,15kHz,20kHz,25kHz,
12kHz,15kHz,20kHz,25kHz,
30kHz,40kHz,50kHz,60kHz,
30kHz,40kHz,50kHz,60kHz,
75kHz,100kHz,
75kHz,100kHz,120kHz,150kHz,
200kHz
Signal source output impedance
Selectable 30Ω, 100Ω, ±1% @1kHz
10mV—2Vrms
Resolution: 10mV,
Normal
Accuracy: 10% x setting voltage+2mV
100μA—20mArms
AC test signal level
Resolution: 0.1mA
------
------
20mV—1Vrms
Constant level
------
------
Resolution: 10mV
Accuracy: 10%
(ALC ON)
------
------
200μA—10mArms
------
------
Resolution: 0.1mA
DCR test signal level
1V DC
1V DC
50mV—2V DC
------
------
Resolution: 0.5mV
------
------
0V— ± 5V
------
------
Resolution: 0.5mV,
DC bias voltage source
Accuracy: 1%
------
------
0mA—± 50mA
------
------
Resolution: 0.5μA
Test parameters
|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR
DCR display range
0.00001 Ω – 99.9999 MΩ
|Z|, R, X
0.00001Ω — 99.9999MΩ
|Y|, G, B
0.00001μs — 99.9999s
C
0.00001pF — 9.99999F
L
0.00001μH — 99.9999kH
LCR parameters display range
D
0.00001 — 9.99999
Q
0.00001 — 99999.9
θ(DEG)
-179.999º — 179.999º
θ(RAD)
-3.14159 — 3.14159
Δ%
-999.999% — 999.999%
Display digits
6
5
6
Measurement time (≥10 kHz)
Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms), Slow: 2.7meas/sec(370 ms)
Equivalent circuit
Serial, Parallel
Range mode
Auto, Hold
Trigger mode
Internal, Manual, External, Bus
Average time
1–255
Correction
Open, Short, Load
Math operation
Direct reading, ΔABS, Δ%
Trigger delay time setting
0 - 60.000s, 1ms steps
Step delay time setting
0 - 60.000s, 1ms steps
·10 points list sweep
List Sweep
·Frequency, AC voltage/current, internal/ external bias voltage/ current can be swept.
·Each sweep point can be sorted separately.
10 bins, BIN1–BIN9, NG, AUX
Comparator function
Bin count function
PASS, FAIL LED display on front panel
Built-in Storage
Internal 100 LCRZ instrument setting files, 201 times test results
USB Storage
Instrument setting files , measurement result CSV files, printed screen (GIF format)
Control interface
HANDLER
Interface
Communication interface
USB HOST, RS232C, RS485(option), GPIB(option)
Storage interface
USB DEVICE (U-disk storage)
Accessories
:
TH26011CS Kelvin test clip leads
TH26048A
4 terminal test fixture
Th26010 Gilded shorting plate
PDF manual
Power cord (US, AU, EURO or AU plug is available)
Note:
1.W
ill ship
to
USA
via
DHL or Fedex
(not for PO Box or APO or FPO), delivery time is about
7 days.
2. Will ship via
express mail service
to Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea, Thailand, Malaysia, Indonesia, Philippine and Singapore customers.
3. Customers from other countries pls contact us in advance to confirm different shipping charges before you order.